chipscopy.sysmon¶
-
class
chipscopy.api.sysmon.
Sysmon
(sysmon_tcf_node)[source]¶ Sysmon is the top level API for accessing System Monitor in Versal.
-
get_all_sensors
(done=None)[source]¶ This function is identical to
get_supported_sensors
in customer releases. For VnC teams this API offers internal sensors. For information on how to use this API please contact @dkopelov or #chipscope.- Parameters
done (
Optional
[DoneHWCommand
]) – Optional command callback that will be invoked when the response is received.- Return type
dict
- Returns
A list of strings representing all sensors for the connected device.
-
get_measurements
(done=None)[source]¶ Advanced API
Returns the measurement objects
- Parameters
done (
Optional
[DoneHWCommand
]) – Optional command callback that will be invoked when the response is received.- Return type
List
[object
]- Returns
Returns a list of measurement configuration objects
-
initialize_sensors
(done=None)[source]¶ Initializes all of the server side constructs for sysmon, required for most subsequent APIs.
- Parameters
done (
Optional
[DoneHWCommand
]) – Optional command callback that will be invoked when the response is received.- Returns
No data is returned directly from this method.
-
read_sensor
(sensor)[source]¶ Read single sensor value from hw :type sensor:
str
:param sensor: the name of the sensor to read- Return type
float
- Returns
refreshed value of specific sensor (float) or None if sensor isn’t detected in design
-
read_sensors
(sensors)[source]¶ Read a list of sensor values from hw :type sensors:
List
[str
] :param sensors: list of the names of the sensors to read- Return type
Dict
[str
,float
]- Returns
refreshed values of specific sensors (float) if the sensor isn’t sequenced in the design then a warning msg is printed and the sensor is dropped from the list
-
read_temp
()[source]¶ Read temp values from hw :param None:
- Return type
Dict
[str
,float
]- Returns
refreshed value of device_temp, max, and min in Celsius
-
refresh_measurement_schedule
(done=None)[source]¶ Dynamically scans the SysMon to determine the sensors scheduled into the system, in order.
- Parameters
done (
Optional
[DoneHWCommand
]) – Optional command callback that will be invoked when the response is received.- Return type
Dict
[int
,str
]- Returns
Returns a dict where the keys are the root IDs and the values are the named sensors.
-
stream_sensor_data
(interval, done=None)[source]¶ This API configures polling in hw_server to stream the data from the measurement schedule (including device temps) at the specified
interval
.To process the incoming data, a dm.NodeListener must be declared and registered on this node.
node_listener = dm.NodeListener(sysmon)
session.chipscope_view.add_node_listener(node_listener)
- Parameters
interval (
int
) – poll period (in ms)done (
Optional
[DoneHWCommand
]) – Optional command callback that will be invoked when the response is received.
- Return type
None
-